High Capacity Standard Size Toggles
Series S
* UL, cULus & CSA recognized only
when ordered with marking on
switch (see General Specs)
DOUBLE POLE WITH SCREW LUG & FLATTED LEVER
Toggle Position/Connected Terminals Electrical Capacity
A
*Approvals
Down
Center
Up
Resistive
Inductive L/R = 3ms
Model
R
C
R
US
Pole &
Throw
Keyway
DC
30V
DC
48V
DC
125V
DC
250V
DC
400V
DC
24V
DC
48V
DC
125V
DC
250V
S821D
DPST
ON
2-3 5-6
NONE OFF
—
30A 30A
20A
15A
4A (10A) 15A 10A
6A
3A
S822D
DPDT
ON
2-3 5-6
NONE ON
2-1 5-4
30A 30A
20A
15A
4A
15A 10A
6A
3A
S823D
DPDT
ON
2-3 5-6
OFF
ON
2-1 5-4
30A 30A
15A
7.5A
—
15A 10A
6A
3A
( ) capacity is due to wiring. Refer to instructions below.
Throw &
Schematics:
DPST
3
2
(COM)
6
5
DPDT
3
2
(COM)
1
6
5
4
Note: Terminal numbers
are on the switch
Notes: Standard Hardware: AT503M Face Hex Nut, AT506M Locking Ring, AT508 Lockwasher, AT527M Backup Hex Nut. See Accessories & Hardware section.
Keyway
M12 P1
M4.5x6
6
Double Pole
3
28°
(42.0)
1.654
(12.5) Dia
.492
(4.0)
.157
(8.15)
.321
(12.0) Typ
.472
5
4
2
1
(9.0)
.354
(3.0) Dia
.118
(12.0)
.472
(9.0)
.354
(27.0)
1.063
(12.0)
.472
(34.0)
1.339
(24.0)
.945
S821D does not
have terminals 1 & 4
Maximum
Panel Thickness:
.177” (4.5mm)
S822D
400V DC WIRING INSTRUCTIONS
1. DC switch use
3. Inductive load
?
?
?
Middle terminal shall be the minus pole when using DC circuit.
Switch case is marked with (+) and (-).
Do not store near (5cm) highly magnetic items.
If actuation is interrupted when switching from ON to OFF, arcing
may continue and switch could be burned.
Inductive loads produce an arc caused by counter-electromotive force
when opening the circuit. Recommend inserting spark elimination cir-
cuit. Contact factory for details.
Contact Point
C
2. Wiring for DC400V 10A
( 2)
(3)
(5)
(6)
R
+
D
L
(Patent Pending)
2
5
Minus Pole
Connection
1
4
Contact Connection Position
4. Compressed terminal connection
When connecting screw terminal with compressed terminal, select
compressed terminal using drawing below.
External
Connection
3
6
Plus Pole
Connection
www.nkk.com
1
2
3
4
5
6
A115